Skip to menu

MRBAS

Room Lighting Control Management

Room Lighting Control Management (
RLCM
)
Background of Development
 The general lighting control system application standard in the domestic building market is applied to medium and large buildings. However, most of small and medium-sized building's luminaires have been changed from fluorescent lighting to LED lighting, and this LED lighting can be controlled in various ways such as dimming control. The need is increasing.

 For example, in the case of a conference room, a variety of scenes such as a seasonal emotional lighting mode, such as a fitness mode, a meeting mode, a power saving mode, and a summertime winter season, are set and used. Like the existing lighting control system, when the PC and software of the central monitoring board were installed, and the on-site dimming control and program switch were installed, the residents often gave up the convenient functions of the lighting control due to the difficulty of construction and excessive investment cost.

 The system developed to solve this problem is Room Lighting Control Management. For a space such as a small office, RLCM (Room Lighting Control Management) is a very suitable system for practical use of lighting control by installing simple minimal equipment and applying only necessary control program.

 The main feature of this system is hardware Auto-Recognition and Plug & Play function. After installing the lighting control products, all items are automatically or manually addressed to each device, and control by the basic program can be operated immediately. And if you want to add more detailed and desired control program, you can add additional program by simple setting method of switch and smart touch switch.

 The KEY equipment of this system is IGS-TS Switch. Up to 31 control modules such as Relay Control Module (4eRM), 0-10v Dimming Control Module (DM010V), and individual LED lighting control are provided in IGS Touch Switch which means individual (I), group (G), and SCENE (S). Connect the available LED Dimming Module (LDM) to the LAN Cable (UTP Cat.6.4Pr). The buttons on the IGS-TS switch allow basic individual, group and scene control. Instead of the IGS-TS switch, STS (Smart Touch Switch) makes the icon button more intuitive, so it can be operated in the same way as the function of the IGS-TS switch.

 In addition, the smart phone with STS-SCH switch and MR BLE APP is applied and operated for more detailed interlock control and schedule control program. When the smartphone and the IGS-TS switch are connected by BLE Bluetooth communication, the MR BLE APP on the smartphone can monitor the state of the currently connected RLCM and additionally set the control program. In the STS-SCH switch, basic control and schedule control programs can be set up and executed, and basic lighting control functions can be operated without installing a separate computer or software.
Overview, Feature & Configuration
The RLCM is to operate a lighting control system with only switches and control modules. Without using a communication device or other software, it is simply installed and basic programs are set up, so basic control can be performed immediately after system installation.

Overview


…EASY Installation : Connect switch and control module by UTP cable or BLE
 wireless communication.
…AUTO Setup Program : Operate default program automatically after installation.
 Program setting by simple switch setting.
…AUTO Pairing : Operate the Set Information of the Switch from Smart-Phone.

Feature


…Each device operates as a basic program after installation & power on. And
 after address setting for each device.
…Basic control operation such as Relay Control Module, 0-10V Dimming Control
 Module by each button of switch.
…To modify the program, when Switch and Control Module is power on, do press
 and hold the Setting Button for few seconds.
…Basic Program for Switch : Individual, Group and Scene Control.
…AUTO Pairing Function : Automatic pairing and information sharing between
 switches and smartphones via Bluetooth communication.
…Basic Time Schedule Control : 8-stage schedule program settings, preset
 holidays and national holidays : For fixes and additional programs, set in the
 smartphone app or STS switch.

Configuration


…Comm : No separate main comm. device and each device is connected with
 UTP.CAT.6.4Pr cable.
…Connect up to 32 devices to one communication line.
…Configured with RPWR(AC220/DC24V.40W), each Switch, Relay & Dimming
 Module.
…Switch in indoor office area, control module in EPS room or JUNCTION BOX  inside ceiling.




System Diagram
The basic configuration of RLCM does not have a main communication device.
The power and communication lines are connected by one common UTP cable.
The system is a compact lighting control system with up to 32 devices connected and operated.



Differentiation
from existing Lighting Control
Our Room Lighting Control Management
(RLCM)
is simple to install and the program comes as standard. It is automatically paired with a smartphone owned by the customer, enabling intuitive lighting monitoring and operation.



The RLCM eliminates the need for central monitoring and power supplies for each control panel. Each device is connected with LAN Cable to operate automatic for Plug & Play Method.



Application
 Differentiation from existing Lighting Control.
Our Room Lighting Control Management (RLCM) is simple to install and the program comes as standard. It is automatically paired with a smartphone owned by the customer, enabling intuitive lighting monitoring and operation. The RLCM eliminates the need for central monitoring and power supplies for each control panel. Each device is connected with LAN Cable to operate automatic for Plug & Play Method.
RLCM Products
Up